Water softener sizing calculator
Work out how many grains of hardness your softener has to remove each day and between regenerations, using the standard formula.
The formula
Grains per day = people × gallons per person per day × hardness (gpg)
Grains between regenerations = grains per day × days between regenerations
Example: 3 people × 82 gallons × 12 gpg = 2,952 grains per day; over 7 days that is 20,664 grains.
Assumptions, and how to change them
- 82 gallons per person per day is the EPA WaterSense figure for average indoor-and-outdoor home use (“Each American uses an average of 82 gallons of water a day at home”, EPA WaterSense). Outdoor irrigation is usually not softened, so if you water a lawn, a lower number may fit your softened use better.
- Hardness should come from a test at your tap. A utility's published figure is a reasonable start; where it publishes a range, the top of the range is the conservative choice.
- 7 days between regenerations is a common starting point, not a rule. More days means a bigger capacity per cycle.
- Iron and manganese also load a softener. This calculator counts hardness only; if your water has iron, check the manufacturer's guidance.
- A softener's rated capacity depends on how much salt it uses per regeneration. Compare the result with the capacity at the salt setting you plan to run, from the manufacturer's spec sheet.
This is arithmetic, not a product recommendation. Water hardness classes: USGS.